Analysis on waterproof insulation construction scheme of rock wool board

The external insulation wall of rock wool board, consisting of four parts, i.e. wall structure layer, insulating layer, protective layer and facing layer, is applied to the external wall of rock wool insulation board, and has good insulation effect. Moreover, it is widely used in such industries as ship, metallurgy, electric power and building. The rock wool products have wide application, are applicable to the industries, such as building, petroleum, electric power, metallurgy, textiles, national defense and transportation, and thus are the ideal material for thermal insulation and sound absorption of pipeline storage tank, boiler, flue, heat exchanger, fan, vehicle and ship and other industries.

1. After mobilization, The rock wool materials must be provided with the factory certificate and inspection report, and can be subjected to the installation construction after passing the reexamination.

2. After the keel is constructed, the fire-proof glass wool insulating layer shall be paved in the keel mezzanine, and the glass wool external insulation wall consists of wall structure layer, insulating layer and facing layer having clear functions. The main key technology to complete the external insulation wall is: connection mode of insulating layer and structure layer.

3. Connection mode of insulating layer and structure layer: the connection mode of insulating layer and structure layer is to fixe with 8*120 expansion bolt, wherein 6 expansion bolts are provided on each glass wool board, the glass wool board is 80 thick and the plaster layer is 15 thick. In order to guarantee that the depth that the expansion bolt is anchored into the structure layer is more than 25, the mark shall be made on the drill to guarantee that the thickness of glass wool board has no negative difference, and moreover, it has convenient construction method and good durability, and is fire-resistant, safe and reliable. (See Fig. I)

4. Installation of rock wool insulation board:

5. Arrangement requirement of rock wool insulation board: staggered paving is

carried out by 1/2 board length along the horizontal direction according to the standard complete breadth (specification: 1200*600) from bottom to top horizontally. The panel shall be vertically staggered, connected and fixed by starting from the

corner of wall, to guarantee that the corner is straight and vertical. The rock wool insulation boards at the external and internal corners are interlocked in the staggered manner. The glass wool at the corners of door and window openings shall not be spliced, the complete rock wool insulation board shall be cut into the notch to be vertical to the board, and the corners of wall shall be pasted and fixed with the same insulation board.

6. The paying mode shall be firstly designed before using the rock wool insulation board. For the calculation size, the clipping and blanking shall be carried out, the straightness error of cut edge shall be less than 5mm, the abutted seam shall not be more than 2mmm, and the gaps between the boards shall be bonded with special adhesive tape.

7. The rock wool insulation board shall be paved by connecting from top to bottom mutually, and shall be paved in order; and when meeting the door and window openings, it shall meet the requirement of relevant atlas. For the treatment of water resistance of rock wool insulation board system and its special parts, the length and width of rock wool insulation board shall be determined according to the site of wall parts. In the process of installing the rock wool insulation board, many construction and installation personnel do not know the sequence of factors. The same rock wool insulation board shall be used at the corner of wall for pasting and fixing.

1. When meeting the door and window openings, the length and width of rock wool board shall be determined according to the site of wall parts.

2. Water resistance and moisture resistance: each rock wool board is packaged with small plastic bag, and before installation, it shall inspect whether the plastic bag is damaged, and the small plastic bag shall be attached in case of damage; before the stone is not hung at the top that the rock wool board has be constructed and is glued, it shall be covered with the plastic cloth to prevent the rain from leaking the interior of glass wool board; the parts exposed at the corner of glass wool board shall be pasted firmly with the aluminum foil strip having the same material with the surface course; and the silicone sealant must be put in the stone seams tightly.

3. Prevention of hot bridge. The iron members embedded on each structural layer shall be welded with the main keel, the embedded parts are called a the hot bridge here, and Portland cement mortar of 15 thick is plastered inside each edge beam to separate the hot bridge.

4. After the fire-proof incombustible glass wool is paved completely, it shall inspect the anchoring point and flatness of glass wool board and bond quality between connected boards, and the dry hanging stone work can be conducted after being qualified. Removal of scaffold: the granite board must be passed the acceptance of supervision unit and wind pressure test and water pouring test after its construction. The removal of scaffold shall be carried out. While the removal of scaffold, the specially-assigned person must guard, to prevent damaging the mobile finished product.

Quality requirements and guarantee measures

5. Basic projects

6. Base treatment

The perpendicularity and flatness shall be within 5mm. Before fixing the board, all

downpipes, line pipes and other embedded parts must be installed completely in

accordance with the requirement of design drawing and construction acceptance

specification. The scaffold shall be above 300mm away from the wall.

7. Clipping of rock wool board

The special knife and saw shall be used, to ensure that the board has accurate size and the clipping opening is neat.

Construction method of external wall insulation of rock wool board

8. Rock wool board

The uniform and straight thickness and width of glass wool board shall be strictly controlled, the consistent combination must be guaranteed, and the corner part shall be lapped in the staggered manner.

9. Requirements of system parts

10. The apparent density of rock wool board shall meet the design requirement.

11. The rock wool board surface shall not be exposed for a long time, and in order to prevent the rock wool board from being affected with damp, each rock wool board is packaged with small plastic bag, the glass wool board shall be covered with the plastic cloth at the top of wall, the rock wool board shall be timely subjected to the application for inspection after installation, the dry hanging stone shall be installed outside it, and the silicone sealant shall be put, to prevent the water seepage when raining.

12. When inspecting, the standard value of tensile bearing capacity of single anchor bolt shall not be less than 0.3KN.

13. When installing the rock wool board, the board slots shall be squeezed tightly, the adjacent boards shall be parallel, the gaps between the board shall not be more than 2mm, and the height difference between the boards shall not be more than 1.5mm.

14. The environment temperature of external insulation construction shall not be lower than 5℃, the construction shall be prohibited in case of gale above Class 5 and rainy weather, the requirement for quality deviation shall conform to the relevant provisions.

락울판 외보온벽체는 벽체 구조층, 보온층, 보호층 및 페이싱층 등 4가지

부분으로 조성되였는데 락울보온판 외벽에 사용되며 양호한 보온효과가 있

어 선박, 야금, 방직, 국방, 교통운수 등 항업에 사용됩니다. 이는 또 도관

저축, 보일러, 연도, 열교환기, 풍기, 차량선박 등 공업설비의 단열, 방음에

이상적인 재료이기도 합니다.

1. 락울재료는 공장에 들어간 후 출하합격증, 검사보고서가 꼭 있어야 하며 공장에 들어간 후 복식합격 진행후 설치시공을 해야 합니다.

2. 용골시공을 마친후 용골중간층에 방화유리면보온층을 펴야 하며 유리면 외보온벽체는 기능이 분명한 벽체 구조층, 보온층, 페이싱층 등 3가지 부분으로 조성되였고 외보온벽체를 잘 하는 주요기술의 관건은 보온층과 구조층의 연결방식입니다.

3. 보온층과 구조층의 연결방식: 보온층과 구조층의 연결방식은 8X120팽창볼트방안을 채용하여 고정하고 매개 유리면판에 6개 팽창볼트, 유리면판 두께는 80, 회칠층은 15, 팽창볼트구조층이 25이상이며 드릴비트에 표기를 하고 유리면판 두께가 부차가 생기지 않도록 하며 시공방법이 편리하고 불에 강하며 안전하고 내구성도 비교적 좋습니다. (첨가 사진1 참고)

4.락울보온판의 설치:

5.락울보온판의 배판요구: 표준에 따라 횡폭(규격: 1200X600)을 아래서부터 위까지 수평방향을 따라 가로로 1/2길이로 교차적으로 깝니다. 벽체 모퉁이로부터 시작하여 수직으로 교차적으로 고정판재를 연결하고 모퉁이가 곧고 수직으로 되도록 해야 합니다. 음양각의 락울보온폰은 교착적으로 인터락되어야 합니다. 문과 창문 4각부분의 유리면은 연결하지 않으며 락울보온판을 자른 자리로 절단하여 판면과 수직되게 하고 벽면의 변각부분은 동일한 보온판으로 붙여 고정시켜야 합니다.

6. 락울보온판은 사용전에 배치방식을 미리 설계해야 합니다. 사이즈를 계산하여 재단하고 재단변두리는 오차가 5mm보다 작아야 하고 패치워크는 2mm보다 크지 말아야 하며 판과 판사이의 틈새는 전용 테이프로 붙여야 합

니다.

7.락울보온판의 배치는 위에서부터 아래로 호상 연결되여야 하며 락울보온판은 순서에 따라 배치하고 문과 창문, 구멍을 발견시 해당 설계의 요구에 부합되여야 합니다. 락울보온판 시스템방수 및 특수부위의 처리는 락울보온판이 외벽보온시 문과 창문, 구멍에 부딪혔을 때 판재 길이, 너비를 벽체부위에 따라 현장에서 확정해야 합니다. 시공설치인원들이 어떤 인소에 따라 동일한 락울보온으로 붙여 고정해야 합니다.

1.문과 창문, 구멍에 부딪혔을 때 판재 길이, 너비는 벽체부위를 현장에서

2.방수방습: 매개 락울판은 플라스틱 포장으로 설치전에 플라스틱 포장에 파손이 있는지를 검사하고 만약 파손이 있을시 작은 플라스틱 포장을 증가하며 락울판 시공이 끝난 후 꼭대기에 석재고무를 설치하기 전에 플라스틱 천으로 잘 덮어놓고 비가 올때 유리면판 내부에 들어가는 것을 방지해야 합니다.

면판 모퉁이 유리면판이 드라난 부위에는 면층과 같은 재질의 알루미늄박조로 붙여 고정하며 석재이음부분에는 실리콘 밀봉테이프로 엄밀하게 붙여야 합니다.

2. 热桥의 발생을 방지해야 합니다. 구조의 매층에 철건과 주용골을 미리

4.방화불연유리면을 설치한 후 유리면판의 닻고정점, 평정도 및 이어진 판들사이의 붙임질량을 검사하고 합격되면 干挂석재사업을 진행할 수 있습니다.비계 제거:화강암 판면 시공을 마친 후 감독단위의 검사와 항풍압 실험, 임수실험을 통과해야 합니다. 피계 제거를 진행합니다. 피계 제거시 전문인원이 관리해야 하며 대리석재제품이 파손되는 것을 방지하고 질량요구 및 보증조치를 담보해야 합니다.

5.기본대상

6.기층처리

수직, 평정도가 5mm이내여야 합니다. 고정판 앞에 모든 수락관, 각종 선관 등 철골은 설계도와 시공험수규범요구에 따라 설치해야 합니다. 피계는 벽체와 300mm이상 떨어져야 합니다.

7.락울판 재단

전용 칼, 톱으로 판재 사이즈가 준확하고 재단이 정갈하도록 해야 합니다. 락울판 외벽보온시공방법.

8.락울판

유리면판의 두께, 너비, 길이가 균등하고 곧아야 하며 결합이 일치하도록 담보하고 모퉁이 부분은

9.시스템 부위의 요구

10.락울판의 표관밀도는 설계요구에 부합돼야 합니다.

11. 락울판 표면은 장기적으로 노출되지 말아야 하며 락울판이 조습하지 않도록 매개 락울판은 플라스틱 포장으로 벽체의 꼭대기에 유리면판을 덮어야 하며 락울판은 설치후 제때에 검사하고 외면에 干挂石材를 설치하며 제때에 실리콘밀봉테이프를 붙이고 비가 올때 물이 스며드는 것을 방지해야 합니다.

12.매개 닻은 항장 적재력 표준치가 0.3KN보다 크거나 같아야 합니다.

13.락울판 설치시 판이음부붇은 긴밀해야 하며 이어진 판은 가지런하고 판사이의 틈새는 2mm보다 작아야 하며 판사이 높이차는 1.5mm를 초과하지 말아야 합니다.

14.외보온시공의 환경온도는 5℃ 보다 낮지 말아야 하며 5급이상의 바람날씨와 비오는 날씨에는 시공을 멈추며 질량편차요구는 해당 규정에 부합되여야 합니다.

Copyright © 2016. Weihai Bosheng Advanced Materials Co., Ltd. All rights reserved. Technical support:Aosion

XML 地图